Created on 12/23/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
FKGB
2-way, pilot shifted, proportional throttle with bleed down, high capacity
SERIES 3 / CAPACITY: 120 L/min. / CAVITY: T-23A
This valve is a 2-way, 2 position, proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
This valve includes a bleed down feature which connects ports 3 to 4 in the spring biased position. The bleed down
feature is useful when the valve is used as a meter-in flow control in circuits which include counterbalance valves
downstream of port 3. The bleed down connection is closed as the valve is piloted with increasing pressure at port
1.
Pressure at port 4 directly opposes pressure at port 1.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 65 cc/min.@70 bar
Pilot Volume Displacement 1,6 cc
Minimum Pilot Pressure to Operate 7 bar
Bypass orifice 0,8 mm
Hysteresis ± 2 %
Adjustment - Number of Clockwise Turns to Increase Setting 5
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-023-007
Seal kit - Cartridge Polyurethane: 990-023-002
Seal kit - Cartridge Viton: 990-023-006
(X)CONTROL
X Not Adjustable
L Tuning Adjustment
(C)SPOOL CONFIGURATION
C Normally Closed
(N)SEAL MATERIAL
N Buna-N
V Viton
snhy.com/
FKGB
TECHNICAL FEATURES
Model Code Example: FKGBXCNCONFIGURATION OPTIONS
Created on 12/23/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic
element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
Ports 1 and 4 should be limited to 500 psi (35 bar).
Pressure at port 4 directly opposes pressure at port 1.
An optional tuning adjustment (L control) is offered to vary the pilot pressure required to control flow. The tuning adjustment provides a means to manually increase
or decrease flow at a given pilot pressure. The adjustment range is 50 - 250 psi (3,5 - 15 bar), 100 psi (7 bar) Standard Setting.
Accurate pressure compensated control requires that a constant pressure differential be maintained across the valve.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.